BESS Solar System
Battery energy storage systems from 96kWh to 5MWh: bidirectional inverters, LFP banks, thermal management and EMS in one tested cabinet.

11 products.
Every model below can be configured for your voltage, grid and destination — send the load profile for a sized proposal.

125KVA 125kW+261kWh BESS Solar System
125kW of power, 261kWh of LFP storage — backup and solar shifting in one cabinet.

100KVA 100kW+215kWh BESS Solar System
100kW of power, 215kWh of LFP storage — backup and solar shifting in one cabinet.

100KVA 100kW+209kWh BESS Solar System
100kW of power, 209kWh of LFP storage — backup and solar shifting in one cabinet.

50KVA 50kW+112kWh BESS Solar System
50kW of power, 112kWh of LFP storage — backup and solar shifting in one cabinet.

40KVA 40kW+96kWh BESS Solar System
40kW of power, 96kWh of LFP storage — backup and solar shifting in one cabinet.

Solar System for House
Rooftop PV, a hybrid inverter and LFP storage configured around household energy use and outage priorities.

Solar System for Farm
Solar for irrigation pumping, cold rooms and farm buildings.

Solar Power System for Hotel
Solar plus storage that protects the guest experience.

Solar System for Factory
Rooftop or ground PV from 100kW to 1MW+, engineered around shift patterns, demand peaks and grid reliability.

1MW 1000kVA Solar System
Complete 1MW solar power system for industrial sites — hybrid-ready.

15KW 15KVA + 50KWH Solar System with Battery
15kW of three-phase power with 50kWh of LFP storage in a single cabinet.
Continue browsing.
The same product can appear in several categories — storage, power rating and application overlap by design.
BESS models at a glance
Six cabinet models cover 96kWh to 261kWh. Usable energy is the nominal capacity taken to 90% depth of discharge, which is the number that decides how long a bank actually carries load.
| Model | Rated power | Nominal capacity | Usable at 90% DoD | Cycle life |
|---|---|---|---|---|
| FS-BESS-96 | 40kW / 40kVA | 96kWh LiFePO4 | 86.4kWh | 6,000+ cycles at 80% EOL |
| FS-BESS-112 | 50kW / 50kVA | 112kWh LiFePO4 | 100.8kWh | 6,000+ cycles at 80% EOL |
| FS-BESS-193 | 80kW / 80kVA | 193kWh LiFePO4 | 173.7kWh | 6,000+ cycles at 80% EOL |
| FS-BESS-209 | 100kW / 100kVA | 209kWh LiFePO4 | 188.1kWh | 6,000+ cycles at 80% EOL |
| FS-BESS-215 | 100kW / 100kVA | 215kWh LiFePO4 | 193.5kWh | 6,000+ cycles at 80% EOL |
| FS-BESS-261 | 125kW / 125kVA | 261kWh LiFePO4 | 234.9kWh | 6,000+ cycles at 80% EOL |
Usable energy equals nominal capacity multiplied by 90% depth of discharge. Containerised projects extend the same architecture to 5MWh; the models above are the standard cabinet sizes.
What the cycle-life figure does and does not tell you.
The table above quotes cycle life at a stated end-of-life condition. That is useful, and it is narrower than it looks.
It is quoted at a stated depth of discharge
Cycle life is a function of how deeply the bank is cycled, among other things. A figure quoted at one depth does not carry over unchanged to a site that routinely cycles deeper.
It is not a calendar life
A bank that is rarely cycled still ages. Sites that hold storage purely for emergencies should ask about calendar ageing as well as cycles, because the two fail in different ways.
It assumes a temperature
Cycle life and usable capacity both move with temperature. In a hot climate the cabinet cooling is not an accessory — it is part of what the cycle-life figure is predicated on. What heat does to storage goes through this properly.
What a BESS quotation should itemise.
Two quotations for the same nominal capacity are not comparable until they break down the same way. These are the lines worth insisting on.
| Line | Why it matters |
|---|---|
| Rated power and nominal capacity | The two are separate; a bank can have the capacity but not the power to deliver it quickly |
| Usable energy at the stated depth of discharge | The figure the site can actually draw, which is not the nameplate |
| Inverter or power conversion | Whether it is included, and what it is rated to carry |
| Enclosure and cooling | Outdoor cabinet with its own cooling, or indoor rack |
| Expansion path | Whether capacity can be added, and what that requires electrically |
| What is not included | Freight, duties, local installation and grid approval are usually separate — see what a quote leaves out |
BESS configurations.
The cabinet range, drawn as it ships.



Frequently asked questions
How long does it take to deliver the BESS Solar System?
End to end, 4–12 weeks. Requirement definition takes 1–3 days, system design 1–2 weeks, production 1–3 weeks, then every unit completes a 72-hour test before shipping, and shipping and installation take 2–6 weeks depending on the destination.
Is the BESS Solar System configuration fixed?
No. What is shown on this page is the reference configuration for the model — every system is sized against its own load data before it is quoted.
What testing does the BESS Solar System go through before shipping?
A 72-hour test. It is the fourth of five steps in our delivery process: requirement definition, system design, production, testing, then shipping and installation.
What is included in the BESS Solar System price?
Every component named on the quotation, plus factory assembly, the 72-hour test, export packing and the documentation set. Not included: sea freight, import duties and taxes, and site labour. Each quotation lists these on separate lines, so you can compare suppliers on the same basis.
Is installation included with the BESS Solar System?
Not as on-site labour. Our scope: the equipment as specified, tested before it ships, with the drawings and documentation your contractor works from, plus remote commissioning support and spare parts. Your scope: the base and civil works, crane placement, AC cable runs, the grid-connection cabinet and metering, local permits, and the installation labour. We do not keep installation crews abroad, so site work and its cost are quoted by your own contractor or local EPC.
Not sure which category fits?
Send the load profile, grid conditions and destination — we will name the architecture and the bill of materials.
Request a system proposal